What was found
EICAS FIRE / OVRHT SYS LIGHT ILLUMINATED WHILE TURNING FINAL UNTIL BOTH ENGINES SHUT DOWN.. MAINTENANCE PERFORMED FIRE / OVHT SYSTEM 6 TC CHECK IAW FIM 26-11 FT 804. NO FAULTS NOTED AT THIS TIME. A/C REMAINS NO ETOPS. PERFORMED GVI OF LOOPS ON NR 1 ENGINE AND PERFORMED MSG CHECK OF #1 ENG LOOPS. OPS CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.