What was found
ON APPROACH TO BOS, NO NOSE GEAR DOWN INDICATION, WENT AROUND (AAP) AND WHILE BEING VECTORED. TESTED LIGHTS AND NOSE GEAR INDICATION TEST NORMAL. GEAR RECYCLE (GRC) FOQA DATA VERIFIES NORMAL GEAR EXTENSION, DOWN AND LOCKED ON BOTH CYCLES INTO BOSTON. PSEU BITE ACCOMP PER AMM 32-09-03 WITH NO FAULTS NOTED. RELAMPED NOSE GEAR DOWN ANNUNCIATOR PER AMM 33-13-00. OK FOR CONTINUED SERVICE. AIRCRAFT RETURNED TO SERVICE.