What was found
EQUIPMENT COOLING SMOKE DISCRETE LIGHT WON'T ILLUMINATE DURING TEST ON GROUND BY MTC. RELAMPED EQUIPMENT COOLING SMOKE DETECTOR LAMP PER B767 AMM 21-58-19. OPS CHECK SATISFACTORY. A/C REMAINS NO ETOPS. A/C RETURNED TO SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EQUIPMENT COOLING SMOKE DISCRETE LIGHT WON'T ILLUMINATE DURING TEST ON GROUND BY MTC. RELAMPED EQUIPMENT COOLING SMOKE DETECTOR LAMP PER B767 AMM 21-58-19. OPS CHECK SATISFACTORY. A/C REMAINS NO ETOPS. A/C RETURNED TO SERVICE.