As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
F/U-CHECK CONNECTORS & WIRING AT FIRE-OVHT TEST PANEL FOR HISTORY OF FIRE/OVHT SYS MESSAGES. IF NFF, REPLACE FIRE/OVHT TEST PANEL. PERFORMED GVI OF FIRE OVHT TEST PANEL CONNECTORS AND WIRING IAW B767 AMM 20-60-03 ALL WIRES LOOK SATISFACTORY WITH NO DAMAGE NOTED, REPLACED OVHT TEST PANEL IAW B767 AMM 26-11-01 OPS TEST GOOD A/C REMAINS NO ETOPS RETURNED TO SERVICE