What was found
DURING C-CHECK & INSPECTION, FUSELAGE SKIN, LOWER SKIN PANEL AT BS 1373, BTWN STR 27R & ABOVE STR 29R WAS FOUND WITH A DENT OUT OF SRM LIMITS 53-00-01, FIG 101, DETAIL 3, & WHILE PERFORMING SRM 53-00-01, REPAIR 14, FOUND DOUBLER TO STOP ON AN INTERNAL DOUBLER & ANGLE OF CUTOUT LOCATION LIGHT. THE PURPOSE OF THIS REA IS TO AUTHORIZE AND DOCUMENT ACCOMPLISHMENT OF REF E, WHICH IS AN FAA-DER APPROVED REPAIR. DAMAGE REPAIRED IAW ABX-REA-5365-66195-00.