What was found
DURING AN INSPECTION, LEFT WING LOWER SKIN EXISTING BLEND REPAIRS AT WS 110, STRINGER 10 WAS FOUND. THE AFFECTED FASTENERS WERE REMOVED, AND HFEC ROTO AND SURFACE INSPECTIONS WERE ACCOMPLISHED WITH NO ADDITIONAL DAMAGE. THE BLEND AFFECTS SKIN PANEL AND SKIN PANEL IAW 57-20-01-1A-ALLOWABLE DAMAGE 1 THE MAXIMUM DEPTH OF CLEANUP IS 0.035" BETWEEN (INBD OF 282.0 WS). DAMAGE REPAIRED IAW FVCI EO 26099-1, & ABX-REA-5725-66013-00.