What was found
DURING C-CHECK, INSPECTION AT FUSELAGE SKIN, LOWER SKIN PANEL, AT BS 1373, BETWEEN STR 27R AND ABOVE STR 29R WAS FOUND DENTED OUT OF SRM LIMITS 53-00-01, FIG 101, DETAIL 3 AND WHILE PERFORMING SRM 53-00-01, REPAIR 14, FOUND DOUBLER TO STOP ON AN INTERNAL DOUBLER AND ANGLE OF CUTOUT LOCATION LIGHT. DAMAGE REPAIRED IAW FVCI EO 26099-13, & ABX- REA-5365-66195-00.