What was found
AFTER DOOR SHUT, SAW SMOKE AT L & R PACK VENTS W/ BURNING ODOR. FOUND NO BURNING ODOR AND RAN THE PACKS AND NO SMOKE FOUND TO BE CONDENSATION FROM PACKS IAW AMM 21-00-00 A/C REMAINS NO ETOPS. A/C RETURNED TO SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFTER DOOR SHUT, SAW SMOKE AT L & R PACK VENTS W/ BURNING ODOR. FOUND NO BURNING ODOR AND RAN THE PACKS AND NO SMOKE FOUND TO BE CONDENSATION FROM PACKS IAW AMM 21-00-00 A/C REMAINS NO ETOPS. A/C RETURNED TO SERVICE.