What was found
WHILE COMPLYING WITH SB 57-129R4, FOUND HOLES IN THE LEFT TRAPEZOID PANEL COMMON TO VERTICAL ATTACH FITTING, OUT OF ROUND AND THE SECOND HOLE FROM BOTTOM STEPPED INSIDE. REPAIRED HOLES IAW DC-9 SRM 51-30-5. STEPPED HOLE REPAIRED IAW ABX REA D957-10786.