What was found
DURING D-CHECK ACCEPTANCE INSPECTION, FOUND THE STEEL PLATE ALONG THE CENTER WINDSHIELD LOWER FRAME RUSTED AND HAD POPPED RIVETS. CLEANED AND TREATED PLATE IAW DC-9 SRM CHAPTER 51-10-3 AND REPLACED FASTENERS IAW DC-9 SRM CHAPTERS 51-30-2, 51-30-5 AND ABX REA D953-10945.