What was found
DURING C-CHECK INSPECTION DURING COMPLIANCE OF AD 90-18-03, SB 57-98, FOUND CORRODED FASTENERS ON RIGHT WING STRINGER NR 18 AT XCW 58. REPLACED WITH HILOCKS IAW DC-9 SRM 51-30-5.