What was found
DURING C-CHECK INSPECTION, FOUND FLC DOOR JAMB WEB PUNCTURED AT STA 383 AND LONGERON 29R. REPAIRED IAW ABX REA D953-11695-MR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK INSPECTION, FOUND FLC DOOR JAMB WEB PUNCTURED AT STA 383 AND LONGERON 29R. REPAIRED IAW ABX REA D953-11695-MR.