What was found
DURING D - CHECK AND MOD ACCEPTANCE INSPECTIONS WHILE COMPLYING WITH AD 90-16-05, SB 57-88, FOUND LEFT WING LOWER SKIN AT XCW 69.5, HOLES A, C, F, I, 4 AND 5 HAVE CRACK LIKE INDICATIONS NOTED BY HIGH FREQUENCY EDDY CURRENT INSPECTION. REPAIRED IAW ABX REA D857-11369-MR.