What was found
DURING C-CHECK INSPECTION, FOUND FLOOR BEAM AT STA 962 HAD A CRACK WHICH EXTENDED PAST STOP DRILL. REPAIRED IAW DC-9 SUPPLEMENTAL SRM DRAWING K05159.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK INSPECTION, FOUND FLOOR BEAM AT STA 962 HAD A CRACK WHICH EXTENDED PAST STOP DRILL. REPAIRED IAW DC-9 SUPPLEMENTAL SRM DRAWING K05159.