What was found
DURING C-CHECK INSPECTION, FOUND SEVERE DENT AND CRACK AT STATION 945, LONGERON 5 RT. INSTALLED NEW FRAME SEGEMENT AT STATION 945 IAW DC9 SRM 51-30-02, 51-30-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK INSPECTION, FOUND SEVERE DENT AND CRACK AT STATION 945, LONGERON 5 RT. INSTALLED NEW FRAME SEGEMENT AT STATION 945 IAW DC9 SRM 51-30-02, 51-30-05.