What was found
DURING C-CHECK, FOUND FLOOR PANEL SUPPORT ANGLE CRACKED AT STA 639. REPLACED IAW DC9 SRM 51-30-2, DOUGLAS DWG. NR 5914617.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK, FOUND FLOOR PANEL SUPPORT ANGLE CRACKED AT STA 639. REPLACED IAW DC9 SRM 51-30-2, DOUGLAS DWG. NR 5914617.