What was found
DURING C-CHECK, FOUND THE RT FLOORBEAM TO KEEL WEB ATTACH FITTING AT FS 585 CRACKED. REPLACED RT FLOORBEAM ATTACH FITTING IAW ABX REA D953-19152-MR, DC9 SRM 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK, FOUND THE RT FLOORBEAM TO KEEL WEB ATTACH FITTING AT FS 585 CRACKED. REPLACED RT FLOORBEAM ATTACH FITTING IAW ABX REA D953-19152-MR, DC9 SRM 51-30-5.