What was found
DURING C-CHECK, FOUND THE LT HINGE FITTING F/STA 1059 FOR AFT VENTRAL DOOR CRACKED. REMOVED AND REPLACED HINGE FITTING IAW DC9 SRM 51-30-1 AND 52-63-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK, FOUND THE LT HINGE FITTING F/STA 1059 FOR AFT VENTRAL DOOR CRACKED. REMOVED AND REPLACED HINGE FITTING IAW DC9 SRM 51-30-1 AND 52-63-00.