What was found
NR 3 PYLON LOWER FORWARD SUPPORT ANGLE AT TOMBESTONE IS CRACKED AT OUTBOARD FASTENER. INSTALLED NEW ANGLE IAW DC-8 SRM 51-3-0 AND DAC DWG NR 9753018.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 3 PYLON LOWER FORWARD SUPPORT ANGLE AT TOMBESTONE IS CRACKED AT OUTBOARD FASTENER. INSTALLED NEW ANGLE IAW DC-8 SRM 51-3-0 AND DAC DWG NR 9753018.