What was found
DURING C-CHECK, FOUND THE FLOORBEAM TO CENTER TANK ATTACH ANGLE AT STA 696, RBL 44 BELOW THE CUSP CRACKED AND CORRODED. REPLACED ANGLE IAW DACO DRAWING 5910464 AND DC9 SRM 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.