What was found
TWO INCH INBOARD OF STA 736.5 CANTED RIB AND APPROXIMATELY 14 AFT OF LEADING EDGE PANEL, RIGHT HAND WING CORRODED OUT OF LIMITS. BLENDED AREA, FABRICATED AND INSTALLED REPAIR DOUBLER IAW ABX REA D857-21372, SRM 51-1-21 AND SRM 51-1-12.