What was found
LOWER L-ANGLE IN KEEL BEAM AREA, BETWEEN WHEEL WELL DOORS, 2ND FROM FRONT (APPROX FS 890) CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED REPLACEMENT ANGLE IAW SRM 51-1-0, 51-1-20D AND 51-1-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LOWER L-ANGLE IN KEEL BEAM AREA, BETWEEN WHEEL WELL DOORS, 2ND FROM FRONT (APPROX FS 890) CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED REPLACEMENT ANGLE IAW SRM 51-1-0, 51-1-20D AND 51-1-21.