What was found
DURING MOD/D-CHECK, FOUND THE AFT VENTRAL DOOR AFT JAMB WEB FS 1135 FRAME CORRODED, LONGERON 24L TO 24R. REPLACED WEB IAW DC9 SRM 51-30-2, AND DACO DWG 9915559.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING MOD/D-CHECK, FOUND THE AFT VENTRAL DOOR AFT JAMB WEB FS 1135 FRAME CORRODED, LONGERON 24L TO 24R. REPLACED WEB IAW DC9 SRM 51-30-2, AND DACO DWG 9915559.