What was found
STATION 620 BETWEEN STRINGERS 35R AND 35L FRAME SPLICE HAS 8 INCH CRACK. REPAIRED IAW DC8 SRM 51-1-20.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STATION 620 BETWEEN STRINGERS 35R AND 35L FRAME SPLICE HAS 8 INCH CRACK. REPAIRED IAW DC8 SRM 51-1-20.