What was found
DURING C-CHECK, FOUND FITTING JUST FWD OF CANTED FRAME STATION 1121 AT VENTRAL STAIR LEFT JAMB CRACKED. REPLACED FITTING IAW DC9 SRM 51-30-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK, FOUND FITTING JUST FWD OF CANTED FRAME STATION 1121 AT VENTRAL STAIR LEFT JAMB CRACKED. REPLACED FITTING IAW DC9 SRM 51-30-1.