What was found
RIGHT WING LEADING EDGE AT STATION XS 250-089 UPPER RIB IS CRACKED ABOVE PNEUMATIC DUCT. FABRICATED REPAIR ANGLE IAW DC8 SRM 57-2-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT WING LEADING EDGE AT STATION XS 250-089 UPPER RIB IS CRACKED ABOVE PNEUMATIC DUCT. FABRICATED REPAIR ANGLE IAW DC8 SRM 57-2-0.