WHILE COMPLYING WITH D-INSPECTION, FOUND CORROSION ON THE PRESSURE PANEL LONGERON TEE CAP AT STATION 604, BETWEEN LONGERONS 29 LEFT AND 29 RIGHT. REPLACED TEE CAP IAW DC9 SRM 51-30-1 AND 51-30-2.