What was found
DURING C-CHECK, FOUND SERVICE DOOR JAMB INTERNAL WEB CRACKED 2 PLACES AT UPPER HINGE CUTOUT, STATION 160. REPAIRED IAW ABX REA D953-25631.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK, FOUND SERVICE DOOR JAMB INTERNAL WEB CRACKED 2 PLACES AT UPPER HINGE CUTOUT, STATION 160. REPAIRED IAW ABX REA D953-25631.