What was found
DURING C-CHECK, FOUND 3 FITTINGS CRACKED AT BOTTOM OF KEEL BEAM BETWEEN MAIN LANDING GEAR DOORS, STATION 940 TO 960. REPLACED KEEL BEAM FITTINGS IAW DC8 SRM 51-3-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK, FOUND 3 FITTINGS CRACKED AT BOTTOM OF KEEL BEAM BETWEEN MAIN LANDING GEAR DOORS, STATION 940 TO 960. REPLACED KEEL BEAM FITTINGS IAW DC8 SRM 51-3-0.