As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING THE REPETITIVE NR 3 ENG SUPPORT FITTING INSP IAW SB 2000-5410A01, AD 2005-19-24, HOLES I, J, K AND L WERE VISUALLY FOUND ELONGATED AND THE HOLES WERE FOUND PREVIOUSLY OVERSIZED TO MAX ALLOWABLE DIA. 0.2817 INCH. FABRICATED FREEZE PLUGS FROM 15-5PH H1025 AND INSTALLED WET WITH BMS10-11, TY1. FABRICATED A RETAINING WASHER. INSTALLED NEW 69-18288-4 AND 69-18227-2 DOUBLERS. DRILLED FASTENER HOLES TO NOMINAL 0.1895 INCH-0.1915 INCH SIZING. INSTALLED FASTENERS AND RETURNED ITEM TO SERVICE WITH AMOC.