What was found
DURING THE REPETITIVE INSP NR 1 ENG PYLON SUPPORT FITTING IAW SB 2000-5410A0 2000-19-24, HOLES I, J, K, AND L WERE VISUALLY FOUND ELEGONGATED AND HOLES WERE FOUND PREVIOUSLY OVERSIZED TO MAX ALLOWABLE DIA. 0.2817 INCH. ENG MOUNT WAS REMOVED AND RE-INSTALLED A NEW MOUNT FITTING. ITEM WAS RETURNED TO SERVICE.