What was found
DURING THE ACCOMPLISHMENT OF A ROUTINE CPCP INSP CARD, A FAIRING ATTACH ANGLE WAS FOUND CORRODED BEYOND LIMITS. THE CORROSION DAMAGE WAS R & R WITH AN ANGLE FABRICATED FROM 0.050" 7075 T6 IAW THE SRM. THE ITEM WAS RETURNED TO SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING THE ACCOMPLISHMENT OF A ROUTINE CPCP INSP CARD, A FAIRING ATTACH ANGLE WAS FOUND CORRODED BEYOND LIMITS. THE CORROSION DAMAGE WAS R & R WITH AN ANGLE FABRICATED FROM 0.050" 7075 T6 IAW THE SRM. THE ITEM WAS RETURNED TO SERVICE.