SDR AFASVRA335

Service difficulty report · G Switch

Difficulty date
December 1, 2006
Submitted
December 1, 2006
Operation
General aviation
Part
G Switch
Condition
Failed
Location
Elt
Part time
9,331 hours
Component
Elt · Dornemargln
Component part number
DMELT61
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ANNUAL INSPECTION TESTING OF ELT IAW AC 43.13-1B, CHAPTER 12, PARA 12-22C. THE G-SWITCH WOULD NOT ACTIVATE. THE NORMAL ON FUNCTIONED SATISFACTORY. WHEN THE ELT WAS AT ROOM TEMPERATURE, G-SWITCH FUNCTIONED PROPERLY BUT WHEN COLD SOAKED IN THE HANGER IT WOULD NOT ACTIVATE. TRIED THE G-SWITCH NUMERIOUS TIMES AND IT WOULD NOT ACTIVATE WHEN COLD. BATTERY EXPIRATION DATE MAR 2007.