What was found
INSPECTION FOUND FLOORBEAM CORRODED AT NUT PLATE MOUNT AREA, STA 1338 BELOW LT AFT LAV. A SPLICE SECTION WAS INSTALLED IAW SRM 51-30-0 AND 51-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOORBEAM CORRODED AT NUT PLATE MOUNT AREA, STA 1338 BELOW LT AFT LAV. A SPLICE SECTION WAS INSTALLED IAW SRM 51-30-0 AND 51-10-3.