What was found
GENERATOR FAIL LIGHT ILLUMINATED ON TAKEOFF. ATTEMPTED RESET AND SMELLED ACRID BURNING SMELL. LANDED AIRCRAFT AT THE NEAREST SAFEST PLACE. REMOVED AND REPLACED VOLTAGE REGULATOR WITH SERVICEABLE UNIT. ALL IAW MM. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GENERATOR FAIL LIGHT ILLUMINATED ON TAKEOFF. ATTEMPTED RESET AND SMELLED ACRID BURNING SMELL. LANDED AIRCRAFT AT THE NEAREST SAFEST PLACE. REMOVED AND REPLACED VOLTAGE REGULATOR WITH SERVICEABLE UNIT. ALL IAW MM. (K)