Service difficulty report · Actuator · Gulstm GVSPG550

Difficulty date
November 30, 2016
Submitted
November 30, 2016
Operation
General aviation
Filed by
AMCR163C
Alticor Inc
Aircraft
N523AC
Make and model
Gulstm GVSPG550
Aircraft serial
5411
Aircraft time
5,411 hours, 1,701 cycles
Part
Actuator
Part number
SYLC526302
Part serial
610
Condition
Out Of Adjust
Location
Apu Inlet Door
Part time
5,411 hours, 540 cycles
Stage of operation
IN
How discovered
V
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WHILE TROUBLESHOOTING AN INTERMITTENT READY LIGHT FOR THE APU INLET DOOR, IT WAS OBSERVED THAT WHEN THE DOOR ACTUATOR RETRACTED, THE SURROUNDING STRUCTURE FLEXED. AFTER ACTUATOR REPLACEMENT, THE REMOVED ONE WAS FOUND TO BE 3/16" TOO SHORT PER THE MAINTENANCE MANUAL SPECS, WHICH WAS LOADING UP THE STRUCTURE. THIS WAS THE ORIGINAL INSTALLED PART FROM THE FACTORY. A SUBSEQUENT CHECK OF ANOTHER G550 FOUND THE SAME CONDITION. MANUFACTURER WAS NOTIFIED. APU HOURS: 625 HRS. VISUAL INSPECTION OF THE SURROUNDING STRUCTURE FOUND NO ANOMALIES.