What was found
STATUS MSG (R TURB OH DET 2) DISPLAYED. FOUND A PIECE OF SAFETY WIRE SHORTING ACROSS THE TERMINALS OF OVERHEAT DETECTION SWITCH. REMOVED WIRE. OPS CHECK GOOD IAW FIMM 26-13-00. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STATUS MSG (R TURB OH DET 2) DISPLAYED. FOUND A PIECE OF SAFETY WIRE SHORTING ACROSS THE TERMINALS OF OVERHEAT DETECTION SWITCH. REMOVED WIRE. OPS CHECK GOOD IAW FIMM 26-13-00. (M)