What was found
CORROSION ON CABIN FLOOR STRUCTURE STA 377.35, RBL 5 TO LBL20. REMOVED CORROSION 377 LBL 20 WITHIN LIMITS 2 AREAS OUT OF LIMITS LBL 10, LBL18 CUTOUT DAMAGE FAB FOR REPAIR ACH ANGLE 2 FILLER AND STRAP PLATE TREATED AREA SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON CABIN FLOOR STRUCTURE STA 377.35, RBL 5 TO LBL20. REMOVED CORROSION 377 LBL 20 WITHIN LIMITS 2 AREAS OUT OF LIMITS LBL 10, LBL18 CUTOUT DAMAGE FAB FOR REPAIR ACH ANGLE 2 FILLER AND STRAP PLATE TREATED AREA SRM.