What was found
FORWARD WASTE TANK BALL VALVE SUPPORT FITTING CORRODED. SUPPORT FITTING REMOVED AND AREA CORROSION CLEANED IAW SRM 51-20-01. AREA CLEANED WAS FOUND BEYOND LIMITS IAW SRM 51-50-02 FIG 01. REPAIRED DAMAGED AREA IAW SRM 51-50-02 FIG 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD WASTE TANK BALL VALVE SUPPORT FITTING CORRODED. SUPPORT FITTING REMOVED AND AREA CORROSION CLEANED IAW SRM 51-20-01. AREA CLEANED WAS FOUND BEYOND LIMITS IAW SRM 51-50-02 FIG 01. REPAIRED DAMAGED AREA IAW SRM 51-50-02 FIG 2.