What was found
DURING THE INSPECTION OF THE LT HORIZONTAL STABILIZER PIVOT BEARING INSPECTION, FOUND THE FOLLOWING ITEMS CORRODED, PIVOT BEARING, OUTER PIN, BEARING RETAINER NUT AND FITTING HOUSING. REPLACED THE PIVOT BEARING, OUTER PIN, BEARING RETAINER NUT AND FITTING HOUSING IAW AMM. FREEPLAY CHECK ACCOMPLISHED IAW AMM. (K)