As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD CARGO FLOOR PANEL 120BF BOTTOM SIDE HAS CORROSION (LIGHT) SEVERAL AREAS MAINLY AROUND FASTNER HOLES BS 440-500. REMOVED CORROSION ON BOTTOM SIDE OF FLOOR PANEL 120 BF 13 PLACES LENGTH 2 INCHES X 2 INCHES. ORIGINAL THICK .080 MATERIAL LOSS .006-.010. FOUND TO BE WITHIN LIMITS IAW SRM. (K)