What was found
BETWEEN STA 1180+20 AND STA 1200 AT BL22L FLOOR STRUCTURE OF CARGO COMPARTMENT HAS LITE SURFACE CORROSION. REMOVED CORROSION IAW SRM THICKNESS .063 MATERIAL LOSS .002 WITHIN LIMITS IAW SRM. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BETWEEN STA 1180+20 AND STA 1200 AT BL22L FLOOR STRUCTURE OF CARGO COMPARTMENT HAS LITE SURFACE CORROSION. REMOVED CORROSION IAW SRM THICKNESS .063 MATERIAL LOSS .002 WITHIN LIMITS IAW SRM. (K)