What was found
FOUND LEFT INTERIOR OVERWING EXIT EMERGENCY LIGHTS OUT, SIDEWALL AND OVER WINDOW. REMOVED AND REPLACED LEFT INTERIOR OVERWING EMERGENCY LIGHTS CHARGER IAW AMM 33-51-51. OPS CHECK NORMAL. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND LEFT INTERIOR OVERWING EXIT EMERGENCY LIGHTS OUT, SIDEWALL AND OVER WINDOW. REMOVED AND REPLACED LEFT INTERIOR OVERWING EMERGENCY LIGHTS CHARGER IAW AMM 33-51-51. OPS CHECK NORMAL. (M)