APU AUTO SHUTDOWN WITH FAULT LIGHT ILLUMINATED IAW FIM 49-11-00 FIGURE 108, INSTALLED REPLACEMENT. LOAD COMPRESSOR INLET TEMP SENSOR IAW AMM 49-61-03, OPERATIONAL CHECK NORMAL. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU AUTO SHUTDOWN WITH FAULT LIGHT ILLUMINATED IAW FIM 49-11-00 FIGURE 108, INSTALLED REPLACEMENT. LOAD COMPRESSOR INLET TEMP SENSOR IAW AMM 49-61-03, OPERATIONAL CHECK NORMAL. (K)