As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO BAY, LT NR 2 FLOOR STRAP IS CORRODED ON LOWER SIDE THROUGHOUT ITS LENGTH. F/S 727D TO 767 LBL 22. REMOVED CORROSION ON AFT CARGO BAY LT NR 2 FLOOR STRAP F/S 727D TO 767, LBL22 IAW MM. ORIGINAL THICKNESS IS 071, MATERIAL LOSS 014, MAX ALLOWABLE LOSS 007 OUT OF LIMITS IAW SRM. FABRICATED NEW FLOOR STRAP IAW 51-40-05/08. (K)