As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND FLOOR STRIP BROKEN IN LT TUNNEL BESIDE NLG BOX STATION 377, LBL 24. REMOVED FLOOR STRIP DAMAGED IAW SRM 51-70-11 FIG 1 FROM STATION 367 TO 377. FABRICATED NEW FLOOR STRIP IAW SRM 51-70-11 FIG 1. TREATED AND PRIMED IAW SRM 51-20-01. INSTALLED REPAIR IAW 51-70-11 AND 51-40-02 STATION 367 TO 377. (M)