As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON BEAM FLOOR SUPPORT UPPER CAP LOWER SURFACE AT BS 377.7, LBL 61. REMOVED CORROSION, SRM 53-00-51-1A FOUND AREA OUT OF LIMITS SRM 53-00-51-2R-3 AND SRM 51-40-02. (K) REMOVED AND REPLACED FLOORBEAM UPPER CAP STATION 377.7 LBL 65 IAW SRM 53-00-51-2R-3 AND SRM 51-40-02. (M)