What was found
TOTAL FUEL DIFFERS FROM CAPT AND F/0 FMC(S) CALCULATED FUEL QTY. FUEL QTY ERROR PROG 2/2 ALERT MSG DISPLAYED ON CDU AND EICAS MSG FMC MESSAGE DISPLAYED FUEL FLOW WAS NORMAL TOTAL FUEL 94.100 LBS FMC CALCULATED 101.300 LBS. TRANSFER TO DMI 436 MEL 28-41-1-2 CAT C. PERFORMED MEL PROCEDURE C/B PULL OUT IAW FIM 34-INDEX FUEL QTY ERROR DISAGREE PROGRESS 2/2, THE FIM 34-61-00 FG 106 SHEET 1 BLOCKS 1-10-20-2-21 WERE PERFORMED, IN ADDITION WAS PERFORMED FIM 28-41-00 SHEET 1 BLOCKS 1-2 SHEET 2 BLOCKS 2-25 THE SYSTEM IS OK , DOES NOT DUPLICATE FAILURE.