As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING APP AT BOG, R HYD QTY DROPPED TO 1 QT WITH THE SYSTEMS PRESSURIZED. THERE WAS NOT R HYD QTY ANNU ON THE EOAP. (THIS CAUSES EMERGENCY LANDING) SEVERE HYD LEAK FOUND AT FWD OUTLET LINE FITTING OF MOTOR OPERATED DUAL SHUTOFF VALVE. DURING INSPECTION FITTING PACKING WAS FOUND BROKEN AND THE FITTING LOOSE. FOLLOWING AMM 29-10-08 P201 NEW TTING AND PACKING INSTALLED. REMAINING LINES VERIFIED FOR PROPER ADJUSTMENT.