What was found
PRELIMINARY REPORT: - PILOT REPORT: DURING LANDING ROLL STRONG TENDENCY TO THE LEFT AFTER BRAKES WHERE APPLIED, NO BRAKING ON RIGHT TANDEM BRAKE TEMPERATURE. 1-395 2-435 3-40 4-40 5-385 6-390 7-40 8-35. IN ACCORDANCE WITH AMM 20-23-11-350-051 ITEM B PROVISIONAL REPAIR (HOSE) WAS INSTALLED ON HYD PARK BRAKE ACCUMULATORS TO CORRECT LEAK ON HYD LINE. PERFORMED OPERATIONAL TEST AND IS SATISFACTORY, TO PERMANENT REPAIR THIS ITEM WAS CONTROLLED UNDER DMI NEF 1125 MEL XVI-I CAT "A" TO NEXT SERVICE. PERFORMED BSCU BITE TEST IN THE TWO CHANNELS, NO FAULT FOUND REF AMM 32-46-00-740 -801. DEACTIVATED BRAKE NR 1 IAW AMM 32-42 -00-040-801. DEFERRED TO DMI 182. MEL 32 -42-01 CAT C.